#### PLEASE NOTE INSTALLATION INSTRUCTIONS

### CHANGES 0.4.0 -> 1.0.0
- Normalize Octaves: Enabled by default. When turned on, the pitch response of all tapes is adjusted by octaves so that the range of samples maps to the same range of input CV, approximately 1.5V - 4.5V when FREQ is set to 0. This can be useful when using SCAN or TAPE TRIGGER, to keep the pitch closer to the range of the original samples, which can sound more natural.
- Quick-clear FREQ setting: Enabled by default. When turned on, press SHIFT+FREQ to clear the FREQ control of both decks to 0.
- V/O 0V calibration point: By default, Spectron outputs a concert C when it recieves a 0V CV at either V/O input, and the FREQ setting is 0. Adjust this setting in the main menu to offset this to whatever pitch you want, for instance if you want to match another oscillator or controller you use often. Also useful if your module falls out of calibration (a full multi-point user calibration option will be available in a future firmware update).
- Added the ability to select between +/- 5V and +/- 10V scaling for FM Index and Sync, X and Y, and Scan CV inputs.

## HOW TO UPDATE:
1. Turn power to the module off.
2. Remove the microSD card from the back of the module and insert it into your computer's microSD card reader. More or less any USB microSD reader should work.
3. Place the file "Spectron_FW_1.0.0_release.20cc" in the folder named "firmware" on the microSD card.
4. It is recommended to delete any other existing files or folders within the "firmware" folder (leave all files in the "tapes" folder - this release contains no updates to the tape files) .
5. Eject the microSD card from your computer and reinsert it into the module.
6. Power on the module while holding the "MTRX" button in the lower left.
7. You should be prompted on the module screen to update to the new firmware (version 1.0.0). You can let go of the MTRX button. Select "OK" with the encoder and push it down to approve.
8. DO NOT power off the device while the firmware is updating!
9. If all goes well, you should boot directly into the new firmware.
10. You can confirm this by entering the main menu (SHIFT + TAPE) and selecting the top option (Device Info)
11. If something goes wrong, or if any instructions are unclear, please contact support@20cc.cool